MITIGASI PENCEMARAN AIRTANAH BEBAS OLEH BBM DARI SPBU 445741 JALAN KLATEN-JATINOM, KECAMATAN KLATEN UTARA, KABUPATEN KLATEN, JAWA TENGAH BERDASARKAN SIMULASI MODEL PENYEBARAN PENCEMARAN BTEX

Pratiwi, Rafika Citra (2023) MITIGASI PENCEMARAN AIRTANAH BEBAS OLEH BBM DARI SPBU 445741 JALAN KLATEN-JATINOM, KECAMATAN KLATEN UTARA, KABUPATEN KLATEN, JAWA TENGAH BERDASARKAN SIMULASI MODEL PENYEBARAN PENCEMARAN BTEX. Other thesis, UPN "Veteran" Yogyakarta.

[thumbnail of 3_Cover_114170075_Rafika Citra Pratiwi.pdf] Text
3_Cover_114170075_Rafika Citra Pratiwi.pdf

Download (68kB)
[thumbnail of 6_Daftar Pustaka_114170075_Rafika Citra Pratiwi.pdf] Text
6_Daftar Pustaka_114170075_Rafika Citra Pratiwi.pdf

Download (154kB)
[thumbnail of 1_Skripsi Full_114170075.pdf] Text
1_Skripsi Full_114170075.pdf
Restricted to Repository staff only

Download (12MB)
[thumbnail of 2_Abstrak_114170075_Rafika Citra Pratiwi.pdf] Text
2_Abstrak_114170075_Rafika Citra Pratiwi.pdf

Download (114kB)
[thumbnail of 5_Daftar Isi_114170075_Rafika Citra Pratiwi.pdf] Text
5_Daftar Isi_114170075_Rafika Citra Pratiwi.pdf

Download (186kB)

Abstract

xiii
MITIGASI PENCEMARAN AIRTANAH BEBAS OLEH BBM DARI
SPBU 445741 JALAN KLATEN-JATINOM, KECAMATAN KLATEN
UTARA, KABUPAEN KLATEN, JAWA TENGAH BERDASARKAN
SIMULASI MODEL PENYEBARAN PENCEMARAN BTEX
Oleh: Rafika Citra Pratiwi
114170075/TL
INTISARI
Air bawah tanah menjadi sumber air bersih yang digunakan sebagian besar
masyarakat di Jebugan, Klaten Utara, Klaten. Namun air bawah tanah rentan terhadap
pencemaran serta akan lebih sulit dibersihkan dari kontaminan. Salah satu potensi
penyebab pencemaran air bawah tanah adalah kebocoran tangki penyimpanan BBM
pada SPBU yang berlokasi di wilayah ini. Kasus kebocoran tangki penyimpanan BBM
pernah terjadi di Indonesia maupun luar negeri yang diakibatkan oleh korosi pada
tangki dan tidak dilakukan pengecekan secara baik. Saat ini tidak terjadi pencemaran
BBM pada lokasi penelitain, akan tetapi tetap ada potensi meskipun kecil. Sehingga
perlu dilakukan pengkajian untuk meminimalisir dampak terjadinya kebocoran.
Tujuan penelitian ini adalah mensimulasikan pencemaran air bawah tanah oleh BTEX
serta arahan mitigasi sebagai upaya meminimalisir dampak terjadinya pencemaran.
Metode yang digunakan dalam penelitian adalah metode kualitatif dan
kuantitatif yang terdiri dari metode survei dan pemetaan, metode uji laboratorium,
metode wawancara, metode matematis, dan metode anilisis deskriptif. Analisis secara
kuantitatif matematis menggunakan analisis numerik metode beda hingga deret Taylor
yang kemudian dibuat simulasi secara spasial. Parameter yang mempengaruhi
perhitungan simulasi yaitu faktor retardasi, konduktivitas hidrolik, gradien hidrolik,
kecepatan aliran, despersivitas longitudinal, dispersi hidrodinamik, konsentrasi
kontaminan, jarak persebaran, lama terjadinya persebaran kontaminan.
Hasil penelitian didaptkan bahwa penyebaran BTEX dari jarak 0-1300 meter
menunjukkan terdapat potensi pencemaran yang berbeda-beda. Faktor yang paling
mempengaruhi dalam persebaran adalah besar konsentrasi sumber. Jarak aman sumur
pada jarak lebih dari 100 meter. Mitigasi dapat berupa pembuatan sumur pantau di luar
SPBU dan pengelolaan kontaminan menggukanan metode pump and treat. Pembuatan
sumur pantau dapat dilakukan di Taman Gergunung di sebelah tenggara SPBU.
Kata Kunci : Air Tanah, Simulasi numerik, BTEX
xiv
MITIGATION OF FUEL GROUNDWATER POLLUTION FROM SPBU
445741 KLATEN-JATINOM STREET, NORTH KLATEN, KLATEN
REGENCY, CENTRAL JAVA BASED ON BTEX POLLUTION SPREAD
MODEL SIMULATION
By: Rafika Citra Pratiwi
114170075/TL
ABSTRACT
Underground water is a source of clean water used by most people in Jebugan,
North Klaten, Klaten. However, groundwater is susceptible to contamination and will
be more difficult to clean from contaminants. One of the potential causes of
groundwater pollution is the leakage of fuel storage tanks at gas stations located in
this area. Cases of fuel storage tank leaks have occurred in Indonesia and abroad
which were caused by corrosion on the tank and not properly checked. Currently there
is no fuel pollution at the research location, but there is still potential, although it is
small. So it is necessary to do an assessment to minimize the impact of leakage. The
purpose of this study is to simulate groundwater pollution by BTEX and mitigation
directions as an effort to minimize the impact of pollution.
The methods used in this research are qualitative and quantitative methods
consisting of survey and mapping methods, laboratory test methods, interview
methods, mathematical methods, and descriptive analysis methods. Quantitative
mathematical analysis uses finite difference method numerical analysis Taylor series
which is then simulated spatially. The parameters that affect the simulation
calculations are the retardation factor, hydraulic conductivity, hydraulic gradient,
flow velocity, longitudinal despersivity, hydrodynamic dispersion, contaminant
concentration, distribution distance, duration of the contaminant distribution.
The results of the study found that the spread of BTEX from a distance of 0-1300
meters indicated that there were different potentials for pollution. The most
influencing factor in the distribution is the concentration of the source. Well safe
distance at a distance of more than 100 meters. Mitigation can be in the form of
constructing monitoring wells outside gas stations and managing contaminants using
the pump and treat method. Making monitoring wells can be done in Gergunung Park
to the southeast of the gas station.
Keywords: Groundwater, Numerical simulation, BTEX

Item Type: Thesis (Other)
Uncontrolled Keywords: Groundwater, Numerical simulation, BTEX
Subjects: T Technology > T Technology (General)
Divisions: Faculty of Engineering, Science and Mathematics > School of Engineering Sciences
Depositing User: Eko Yuli
Date Deposited: 22 Feb 2023 02:59
Last Modified: 22 Feb 2023 02:59
URI: http://eprints.upnyk.ac.id/id/eprint/32714

Actions (login required)

View Item View Item