Herianto, Herianto and Asmorowati, Dewi (2021) Optimization of Flashing Pressure Separator and Turbine Thermal Efficiency on Mini-Scale Geothermal Power Plant at Utilization Exploration Well. In: 3rd International Conference on Earth Science, Mineral, and Energy AIP Conf. Proc. 2363, 020018-1–020018-7, 23 November 2021, Bandung.
Text
B-5.2. Paper-Optimization of flashing pressure separator and turbine thermal efficiency on mini-scale.pdf Download (825kB) |
Abstract
In drilling geothermal exploration wells, sometimes a small capacity is obtained that produces a small amount
of electrical energy. In some remote areas, the need for electricity is vital, because the distribution of electricity from the
government sometimes does not reach these areas. For this reason, a mini-scale power plant with a capacity of fewer than
10 MWe is needed to meet the needs of electrical energy, especially in these areas. This research tries to make a mini�scale geothermal using two-phase exploration well data with a pressure of 11 bar, the temperature of 180 oC, the mass
flow of 100 kg/s, and drought of 23%. In this case study, the optimization of pressure separator flashing was carried out
to obtain optimal energy. Based on the calculation results, the optimum separator flashing pressure is obtained at 4 bar
where the 7 bar turbine inlet pressure produces 9.96 MWe with a thermal efficiency of 73%.
Keywords: Mini-scale power plant, Flashing Separator Pressure, Thermal Efficiency.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | Mini-scale power plant, Flashing Separator Pressure, Thermal Efficiency. |
Depositing User: | Dr. Ir. MT HERIANTO TOPAN |
Date Deposited: | 10 May 2022 06:46 |
Last Modified: | 10 May 2022 06:46 |
URI: | http://eprints.upnyk.ac.id/id/eprint/29729 |
Actions (login required)
View Item |