Prayoga, Oktavian (2016) KUALITAS AIRTANAH DI SEKITAR PABRIK TEKSTIL PT UNGGULREJO WASONO BERDASAR PARAMETER pH, DO, TDS DAN DHL, DESA KLEDUNG KRADENAN, KECAMATAN BANYU URIP, KABUPATEN PURWOREJO, JAWA TENGAH. UNSPECIFIED thesis, UPN "Veteran" Yogyakarta.
Preview |
Text
ABSTRAK.pdf Download (182kB) | Preview |
Preview |
Text
COVER SKRIPSI.pdf Download (128kB) | Preview |
Preview |
Text
DAFTAR ISI.pdf Download (115kB) | Preview |
Preview |
Text
HALAMAN PENGESAHAN.pdf Download (852kB) | Preview |
Abstract
Tujuan penelitian adalah untuk mengetahui kualitas airtanah bebas berdasarkan
parameter pengukuran pH, DO, TDS dan DHL yang mengacu pada Peraturan
Pemerintah Rebuplik Indonesia No. 82 tahun 2001 tentang Pengelolaan Kualitas Air dan
Pengendalian Pencemaran Air Golongan I di Kawasan Permukiman di sekitar industri
pabrik tekstil di Desa Kledung Kradenan, Kecamatan Banyu Urip, Kabupaten
Purworejo, Jawa Tengah, serta untuk mengetahui status mutu air pada airtanah dengan
metode indeks pencemaran.
Tahap awal penelitian yang dilakukan yakni membuat Peta Flownet untuk
mengetahui arah aliran airtanah agar dapat menentukan titik – titik pengambilan sampel
airtanah dengan cara mengukur ketinggian sumur – sumur warga di lokasi penelitian.
Metode penelitian yang digunakan adalah metode survey, uji laboratorium dan indeks
pencemaran. Teknik sampling yang digunakan adalah systematic random sampling
dengan 10 titik pengamatan yakni pada setiap grid yang telah dibuat berdasarkan
metode Systematic Random Sampling. Semua sampel air yang telah diambil tersebut
dianalisis di laboratorium dengan parameter DO, TDS dan DHL, sedangkan parameter
pH diuji dengan menggunakan kertas lakmus yang dilakukan langsung di lapangan.
Hasil yang didapat dari pengukuran dibandingan dengan bakumutu lalu dihitung nilai
indeks pencemarannya dengan menggunakan metode indeks pencemaran.
Berdasarkan Hasil pengujian laboratorium pada parameter pH, DO, TDS dan
DHL menunjukan bahwa hampir semua sampel tidak melebihi baku mutu. Kandungan
pH pada sampel TS 1 – TS 10 tidak melebihi baku mutu. Parameter DO terendah pada
TS 4 dan TS 10 yaitu 4,6 mg/L. Parameter TDS tertinggi pada TS 4 yaitu 1160,2 mg/L.
Untuk perhitungan DHL pada tiap titik sampling menunjukan bahwa setiap titik hampir
tidak memiliki nilai DHL atau mendekati nilai 0. Dari analisis keempat parameter
dengan metode indeks pencemaran dapat disimpulkan bahwa status mutu air di daerah
penelitian pada dua titik sampel yaitu titik sampel 4 dan 10 termasuk dalam kategori
tercemar ringan.
Kata kunci : Industri tekstil, kualitas airtanah, Pencemaran
The purpose of the study was to test the quality of unconfined aquifer based
on pH, DO, TDS and DHL parameters compared to Peraturan Pemerintah Republik
Indonesia No 82 tahun 2001 on the Management of Water Quality and Water
Pollution Control Group I and to test unconfined aquifer pollutant index at Kledung
Kradenan Village and surroundings, Banyu Urip district, Purworejo, Central Java, As
well as to find out the status of water quality in groundwater pollution index method .
The initial stage of the study conducted to make Flownet Map to know the
direction of groundwater flow in order to determine the sample point by measuring
the height of groundwater wells at the research area. The methods used in this
research are survey, laboratory test and pollutant index. The sampling technique
applied was systematic random sampling using 10 observation points on each sample
grid. All the water sample were analyzed in laboratory, all the samples were
measured for each parameter, those are DO, TDS and DHL whilst pH parameter
tested by using litmus paper on the field. Results obtained from measurements
compared with the quality standards and pollution index value is calculated using the
pollution index .
Based on the results of laboratory testing on the parameters of pH, DO, TDS
and DHL, showed that almost all of the samples did not exceed the quality standards.
The content of the pH of the sample TS 1 - TS 10 does not exceed the quality
standards, the lowest DO parameters on TS 4 and TS 10 are 4,6 mg / L. The highest
TDS parameters on TS 4 is 1160,2 mg / L. For DHL analysis on each samples point
shows that all points almost getting 0 point. Analysis of the four parameters with
pollution index method can be concluded that the status of water quality in the area
of research on two sample points which sample points 4 and 10 are included in the
category of lightly polluted .
Keywords: textile industry, unconfined water quality, Pollution
Item Type: | Thesis (UNSPECIFIED) |
---|---|
Subjek: | T Technology > T Technology (General) |
Divisions: | x. Faculty of Engineering, Science and Mathematics > School of Engineering Sciences |
Depositing User: | Eko Yuli |
Date Deposited: | 26 Sep 2016 06:14 |
Last Modified: | 26 Sep 2016 06:14 |
URI: | http://eprints.upnyk.ac.id/id/eprint/6731 |
Actions (login required)
![]() |
View Item |