Galih Aji Mahatma, Nifwanto (2016) KAJIAN KUALITAS AIRTANAH DANGKAL AKIBAT LIMBAH PETERNAKAN SAPI (Studi Kasus di Desa Sorogenen, Kecamatan Sewon, Kabupaten Bantul, Provinsi Daerah Istimewa Yogyakarta). Other thesis, UPN "Veteran" Yogyakarta.
|
Text
cover.pdf Download (224kB) | Preview |
|
|
Text
abstrac skripsi.pdf Download (85kB) | Preview |
|
|
Text
DAFTAR ISI.pdf Download (264kB) | Preview |
|
|
Text
Lembar pengesahan.pdf Download (558kB) | Preview |
Abstract
Penelitian ini bertujuan untuk mengetahui kualitas airtanah dangkal menggunakan Indeks Pencemaran ditinjau dari parameter Kekeruhan, pH, BOD, COD, amonia (NH3), Nitrat dan bakteri E.coli di daerah penelitian. Metode penelitian yang digunakan adalah metode survei, metode analisis laboratorium dan metode Indeks Pencemaran. Peta pesebaran pencemaran airtanah didapat dari nilai perhitungan Indeks Pencemaran. Parameter yang dipakai seperti kedalaman muka airtanah, topografi, media akuifer, aliran airtanah. Berdasarkan Peraturan Gubernur Daerah Istimewa Yogyakarta Nomor 20 Tahun 2008 tentang Baku Mutu Air di Provinsi Daerah Istimewa Yogyakarta yang diperuntukan sebagai air minum Kelas I, kandungan Kekeruhan pada TS 1 sampai 6 tidak melebihi baku mutu, kandungan pH pada TS 1 sampai TS 6 tidak melebihi baku mutu. Parameter BOD pada TS 1 sampai TS 6 melebihi baku mutu. Kandungan COD pada TS 1, TS 4, TS 5 melebihi baku mutu. Kandungan amonia tertinggi pada TS 2 yaitu 0,55 mg/L. Kandungan Nitrat pada TS 1 sampai TS 6 tidak melebihi baku mutu. Kandungan bakteri E.coli pada TS 1 sampai TS 6 tidak melebihi baku mutu. Persebaran pencemaran airtanah di daerah penelitian pada lokasi 1 sampai 6 termasuk ke dalam tingkat tercemar ringan. Alternatif arah pengelolaan di daerah penelitian yaitu menjaga kebersihan kandang dan pembuatan instalasi pengolahan air limbah komunal. Kata Kunci : Peternakan sapi, Metode Indeks Pencemaran, This study aims to determine the quality of shallow groundwater use Pollution Index in terms of the parameters Turbidity, pH, BOD, COD, ammonia (NH3), nitrates and bacteria E.coli in the study area. The method used is a survey method, laboratory analytical methods and method Pollution Index. Distribution map obtained from the groundwater pollution Pollution Index value calculation. Parameters that are used as the depth of groundwater table, topography, media aquifers, groundwater flow. Based regulation of Yogyakarta Special Region Government Rules Number 20 of 2008 concerning on Water Quality Standard in the Yogyakarta Special Region for Class I drinking water, the content of turbidity at TS 1 to 6 does not exceed the quality standards, the content of pH on TS 1 to TS 6 is not exceeded quality. Parameter BOD at TS 1 to TS 6 exceeds quality standards. The content of COD in TS 1, TS 4, TS 5 exceeded the standard quality. The highest ammonia content of the TS 2 is 0.55 mg / L. Nitrate content of the TS 1 to TS 6 does not exceed the quality standards. E.coli bacteria content at TS 1 to TS 6 does not exceed the quality standards. Distribution of groundwater contamination in the area of research on locations 1 to 6 included into lightly polluted level. Alternative management direction in the area of research that keep cleaning the cage and manufacture of communal waste water treatment plant. Keyword: Cattle Farm, pollution Index,
Item Type: | Thesis (Other) |
---|---|
Subjects: | T Technology > TD Environmental technology. Sanitary engineering |
Divisions: | Faculty of Engineering, Science and Mathematics > School of Engineering Sciences |
Depositing User: | Eny Suparny |
Date Deposited: | 19 Aug 2016 04:07 |
Last Modified: | 19 Aug 2016 04:07 |
URI: | http://eprints.upnyk.ac.id/id/eprint/5471 |
Actions (login required)
View Item |