EVALUASI PENCEMARAN AIR LINDI TERHADAP PERTANIAN DAN PERMUKIMAN DI TPA BANYUROTO, DESA BANYUROTO, KECAMATAN NANGGULAN KABUPATEN KULONPROGO, YOGYAKARTA

Indrian, Setya Ady (2012) EVALUASI PENCEMARAN AIR LINDI TERHADAP PERTANIAN DAN PERMUKIMAN DI TPA BANYUROTO, DESA BANYUROTO, KECAMATAN NANGGULAN KABUPATEN KULONPROGO, YOGYAKARTA. Other thesis, UPN "Veteran" Yogyakarta.

[thumbnail of Abstract.pdf]
Preview
Text
Abstract.pdf

Download (19kB) | Preview

Abstract

Along with population rise and living needs rise so that it would produce a
huge disposal material, therefore the building of Rubbish Final Disposal Site
(TPA) was needed to rubbish managementin an area, however the development
also had a negative effect to the nearby site. The effect emerged due to the TPA
was soil water quality effect around TPA location. This research was conducted in
Final Rubbish Disposal of Banyuroto inBanyuroto village, Nanggulan District,
Kulon Progo Regency, Yogyakarta Special Region. The purpose of this research
was to know how big waste water effectto oil water quality around TPA of
Banyuroto was and to know waste water-free contaminated soil water spread
pattern so that it could give information or description on soil water quality
condition in the research area.
The research used a survey and analytical method. Survey method was
conducted by a field direct observation for analysis method namely by analyzing
laboratory sample test laboratory and then compared the laboratory test result by
quality standard determined.
For soil water quality test, it was conducted soil water sample taking as
much as 10 points based on soil water flow direction by a parameter tested namely
TDS, pH, BOD, COD, and heavy metal (lead and chrome). Out of laboratory test
result, nature value of BOD, COD, and TDS there were some points exceeded
quality standard to the maximum value was in point S2 (outlet) with each value of
BOD=200.1 mg/l; COD=750 mg/l; and TDS=2,640 mg/l. Quality standard still
tended to neutral ranged between 6.8–8.2 was still under quality standard. Heavy
metal parameter itself was still far under quality standard that was for lead value
<0.0093 mg/l and for chrome value <0.0014 mg/l.
Keywords: Evaluation, Waste water, Banyuroto

Item Type: Thesis (Other)
Subjek: Q Science > Q Science (General)
Divisions: x. Faculty of Engineering, Science and Mathematics > School of Civil Engineering and the Environment
Depositing User: Mr Suninto Prabowo
Date Deposited: 07 Jun 2016 01:31
Last Modified: 07 Jun 2016 01:31
URI: http://eprints.upnyk.ac.id/id/eprint/3068

Actions (login required)

View Item View Item