Herianto, Herianto (2021) Re-Design of Electric Submersible Pump to Increase Production with Variable Stage and Frequency Sensitivity: Case Study Well “JTB-89”. In: 3rd International Conference on Earth Science, Mineral, and Energy, 25 November 2020, Yogyakarta.
Text
B-6.2. Paper-Re-design of electric submersible pump to increase production with variable stage and freq.pdf Download (616kB) |
Abstract
Abstract -- The JTB-89 well has been produced with an artificial lift method, which is the Electrical Submersible Pump,
and type DN1100 / 47 Hz / 130 stages has been installed with fluid rate of 716 bfpd, oil production rate of 168 bopd, and
76% water cut with pump setting depth (PSD) of 4910.1 ft [8]. Based on Inflow Performance Relationship (IPR), this well
needs to be optimized. If re-design is done, production capability can reach ± 70% of the maximum production rate.
Therefore, it is necessary to increase production rates by evaluating pump setting depth (PSD), frequency, head/stages, and
the number of stages on the installed ESP. After evaluating the installed pump, this well does not require to alter the pump
type because of pump capacity is still in range. By changing the design of head/stages to 30 ft, increasing frequency to 65
Hz, an increasing number of stages to 160 stages, and increasing PSD to 6750 ft, this design can increase fluid rate
production to 1006.85 bfpd
Keyword : Electric Submersible Pump (ESP), Pump Setting Depth (PSD), Stages, Frequency.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | Electric Submersible Pump (ESP), Pump Setting Depth (PSD), Stages, Frequency. |
Subjects: | T Technology > TN Mining engineering. Metallurgy |
Divisions: | Faculty of Engineering, Science and Mathematics > School of Engineering Sciences |
Depositing User: | Dr. Ir. MT HERIANTO TOPAN |
Date Deposited: | 07 Apr 2022 01:49 |
Last Modified: | 07 Apr 2022 01:50 |
URI: | http://eprints.upnyk.ac.id/id/eprint/29356 |
Actions (login required)
View Item |