WIJAYA, FAUZIA RIZKY (2018) ANALISIS MASS BALANCE FLUIDA RESERVOAR GEOTHERMAL DAN INTERPRETASI GEOLOGI BAWAH PERMUKAAN BERDASARKAN METODE MICROGRAVITY PADA LAPANGAN “Z” MASS BALANCE FLUID OF RESERVOIR GEOTHERMAL ANALYSIS AND GEOLOGICAL SUBSURFACE INTERPRETATION BASED ON MICROGRAVITY METHOD IN “Z” FIELD. Other thesis, UPN "Veteran" Yogyakarta.
|
Text
ABSTRAK_FAUZIA RIZKY WIJAYA_115140108.pdf Download (347kB) | Preview |
Abstract
ABSTRAK Lapangan geothermal “Z” merupakan bagian dari lapangan geothermal Kamojang, Kec. Ibun, Kab. Bandung, Jawa Barat. Lapangan tersebut telah beroperasi sejak tahun 1983 dengan jenis reservoar dominasi uap. Lapangan geothermal perlu dilakukan monitoring agar mengetahui perubahan yang terjadi disebabkan oleh kegiatan produksi yaitu berkurangnya massa fluida. Dengan diketahuinya perubahan tersebut sehingga dapat dilakukan penanganan yang tepat agar umut lapangan geothermal tetap bertahan dan menjadi sustainable energy. Salah satu dari metode geofisika yang dapat digunakan dalam kegiatan monitoring lapangan geothermal yaitu metode microgravity. Data yang digunakan pada penelitian kali ini yaitu data microgravity pada tahun 1997 serta 1999 yang kemudian dilakukan pengolahan serta koreksi sehingga didapatkan nilai delta g serta ABL. Data delta g digunakan untuk interpretasi perubahan fluda reservoar. Data ABL digunakan untuk interpretasi geologi bawah permukaan seperti struktur dan litologi. Kedua data tersebut digunakan untuk mengetahui hubungan penyebab dari perubahan fluida dengan geologi pada lapangan “Z”. Analisis mass balance dilakukan dengan menggunakan metode gauss mass calculation dengan tujuan memberikan rekomendasi manajemen reservoar agar tetap seimbang antara fluida recharge dengan fluida discharge. Berdasarkan peta delta g dihasilkan rentang nilai delta g antara 31.098 mikrogal sampai -56.185 mikrogal. Dengan pola anomali delta g positif pada bagian barat daya serta timur peta dan anomali negatif pada bagian tengah peta. Pada peta ABL dihasilkan dengan rentang nilai antara 12.09 mgal – 6.39 mgal. Berdasarkan filter Total Horizontal Derivative didapatkan 4 pola strutur berarah timur laut – barat daya, barat laut – tenggara, barat – timur, serta pola struktur kaldera. Berdasarkan analisis mass balace terdapat defisit antara massa fluda recharge dengan fluida discharge sebesar 7.18 juta ton dalam waktu 2 tahun (pada tahun 1997 – 1999). Kata kunci : Mass balance, microgravity, ABL, gauss mass calculation, struktur fluida. ABSTRACT Geothermal field “Z” is part of geothermal field Kamojang, Ibun, Bandung district, West Java Province. The field already operated since 1983 with reservoir type is vapour dominated. Geothermal field need to be monitored to know the changes that caused by production activity one of them is decreasing fluid mass. Knowing that changes so we know the proper handling to keep the lifetime of geothermal field and become sustainable energy. One of geophysical method that can be used to monitoring activitiy is microgravity method. The data that used in this research are microgravity data in 1997 and 1999 which is then processed and corrected so that obtained value of delta g and CBA. CBA data used for geological subsurface interpretation such as structure and litology. Both of data used to know the relationship between changes of fluid with geological condition in field “Z”. Mass balance analysis is carried out using gauss mass calculation method with the aim to providing a recomndation reservoir management to keep balance between recharge fluid with discharge fluid. Based on delta g map generated value of delta g between 31.098 mikrogal until -56.185 mikrogal. Positive Anomaly of delta g are found in south west and east of the map and negative anomaly is found in middle area of the map. On CBA map generated range value between 12.09 mgal – 6.39 mgal. Based on Total Horizontal Derivative filter provided 4 struture patern with direction north east – south west, north west – south east, west – east, and caldera structure. Based on mass balance analysis there are a deficit between recharge fluid with discharge fluid in the amount of -7.18 million ton in 2 years (1997 – 1999). Keywords : mass balance, microgravity, CBA, gauss mass calculation,structure, fluid.
Item Type: | Thesis (Other) |
---|---|
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Engineering, Science and Mathematics > School of Engineering Sciences |
Depositing User: | Ratna Sufiatin |
Date Deposited: | 21 Jan 2019 06:09 |
Last Modified: | 21 Jan 2019 06:09 |
URI: | http://eprints.upnyk.ac.id/id/eprint/18078 |
Actions (login required)
View Item |