KAJIAN FOIrENSI TINGKAT PTNCEMARAN SENTAWA LOGAM BERAT ION Cu, CT DAN Fe PADA AIRTANAH BEBAS DI AREA TPA CIPAYTJNGK, OTA DEPOK PROVINSIJ AWA BARAT

Ekodono, Arlen (2016) KAJIAN FOIrENSI TINGKAT PTNCEMARAN SENTAWA LOGAM BERAT ION Cu, CT DAN Fe PADA AIRTANAH BEBAS DI AREA TPA CIPAYTJNGK, OTA DEPOK PROVINSIJ AWA BARAT. Other thesis, UPN "VETERAN" YOGYAKARTA.

[thumbnail of ABSTRACT.pdf]
Preview
Text
ABSTRACT.pdf

Download (26kB) | Preview
[thumbnail of COVER.pdf]
Preview
Text
COVER.pdf

Download (381kB) | Preview
[thumbnail of DAFTAR ISI.pdf]
Preview
Text
DAFTAR ISI.pdf

Download (43kB) | Preview
[thumbnail of LEMBAR PENGESAHAN.pdf]
Preview
Text
LEMBAR PENGESAHAN.pdf

Download (149kB) | Preview

Abstract

Cipayung final disposal (TPA) is part of a public facility that can be utilized by
Depok people. Currently, the disposal area that owned by Depok City Government is
approximately 11.2 hectares. The purpose of this study were : (1) Analizing the potential
contamination of heavy metals Cu, Cr and Fe ion on groundwater in the Cipayung
disposal area, (2) Re-design the Cipayung disposal area wastewater treatment plant. The
study was conducted in Cipayung District, Depok City, West Java Province in October
during the dry season.
The method used in this research were surveying and mapping, laboratory
testing, and Le Grand scoring method that used to determine physical parameters such as
: (1) Depth of Groundwater level, (2) Slope of Groundwater level, (3) Absorption Above
The Groundwater level, (4) Well Horizontal Distance With The Pollutant Resources, (5)
Aquifer Permeability. Laboratory test was conducted to determine the levels of chemical
parameters such as BOD, COD, Total Iron (Fe), Copper (Cu), Total Chromium (Cr) and
pH. Laboratory test results will be use as a comparison standard quality based on
Government Regulation No. 82 of 2001 concerning Water Quality Management and
Water Pollution Control and the Regulatory of Environment Minister No. 5 of 2014
concerning Wastewater Quality Standard.
Based on the scoring results of each parameter using the Le Grand method at 19
point of wells sampling, obtained a small contamination potential class (very
improbable) and moderate (possible but not likely). The further the location of the wells
with pollutant resources (Final Disposal) the smaller the level of the contamination. The
proper management direction that can be done to reduce the level of leachate water
pollution in the Cipayung final disposal area is redesign the wastewater treatment plant
(WWTP) that accordance with the characteristics of Cipayung final disposal leachate.
Keywords : Potential Contamination, Groundwater, Le Grand, Contamination level

Item Type: Thesis (Other)
Subjek: T Technology > TG Bridge engineering
Divisions: x. Faculty of Engineering, Science and Mathematics > School of Civil Engineering and the Environment
Depositing User: Sarimin Sarimin
Date Deposited: 17 May 2016 01:59
Last Modified: 17 May 2016 01:59
URI: http://eprints.upnyk.ac.id/id/eprint/1084

Actions (login required)

View Item View Item